PDU3EVN6L2130
$ 2406.34
The PDU3EVN6L2130 8.6kW 3-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Recommended for IT and industrial applications, it features 45 outlets-36 C13 (208V), 6 C19 (208V) and 3 NEMA 5-15/20R (120V)-with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with NEMA L21-30P input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A color touchscreen LCD lets you toggle between menus to monitor input current level per phase and output current per load bank with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the PDU through a mobile device.

The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.
SKU PDU3EVN6L2130
Weight 17.75 lbs
Manufacturer: Tripp Lite
Catalog Page Number: 0
  • Main Features
  • Technical Specifications

Main Features

PDU Type:Monitored
Phase:Three Phase
Plug/Connector Type:NEMA L21-30P
Receptacle Type:
  • IEC 60320 C19
  • IEC 60320 C13
  • NEMA 5-15/20R
Receptacle Detail:
  • 6 x IEC 60320 C19
  • 36 x IEC 60320 C13
  • 3 x NEMA 5-15/20R
Protection Type:Overload Protection
Input Voltage:230 V AC
Output Voltage:
  • 120 V AC
  • 208 V AC
Power Rating (Watt):8.60 kW
Input Current:24 A
Management:Protocols:
  • IPv4
  • IPv6
  • HTTP
  • HTTPS
  • SMTP
  • SNMPv1
  • SNMPv2
  • SNMPv3
  • telnet
  • SSH
  • FTP
  • DHCP
  • NTP
Network (RJ-45):Yes
Mounting Orientation:Vertical
Mount Type:Rack-mountable
Rack Height:0U
Height:70" (1778 mm)
Width:2.17" (55.12 mm)
Depth:2.52" (64.01 mm)
Weight (Approximate):6.12 kg
Package Contents:
  • PDU3EVN6L2130 45-Outlet PDU
  • Configuration Cable
  • 42 x Plug-lock Insert Sleeves
  • Rack-mounting Hardware
  • Mounting Bracket Accessory
  • Owner's Manual
Environmentally Friendly:Yes
Country of Origin:Taiwan
TAA Compliant:Yes
Limited Warranty:2 Year

Marketing information

The PDU3EVN6L2130 8.6kW 3-Phase Monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via built-in network connection. Recommended for IT and industrial applications, it features 45 outlets-36 C13 (208V), 6 C19 (208V) and 3 NEMA 5-15/20R (120V)-with included plug-lock insert sleeves to prevent cables from becoming accidentally disconnected. A six-foot cord with NEMA L21-30P input plug connects the 3-phase PDU to a compatible AC power source, generator or protected UPS.

The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

A color touchscreen LCD lets you toggle between menus to monitor input current level per phase and output current per load bank with ±1% billing-grade accuracy, environmental sensor data and network information. It also generates a unique QR code to allow access to the PDU through a mobile device.

The 0U PDU mounts vertically in racks using the included toolless mounting buttons or the included rack-mounting brackets. Use the included PDUMVROTATEBRKT kit to install the unit with outlets facing the rear for better airflow or equipment access.

Send to friend

: *
: *
: *
 

Customer Reviews

There have been no reviews for this product.

Other products to consider